GM700

Rightest glucose meter

GM700

Functional Optimization with Professional Medical Specifications

The new glucose dehydrogenase reagent can detect a variety of blood samples, tailored for medical needs to take care of you more comprehensive.

pro-img/08 GM700/En/01_GM700_mmol.jpg
pro-img/08 GM700/En/02_GM700_mmol.jpg
pro-img/08 GM700/En/03_GS700.jpg
pro-img/08 GM700/En/04_GD500.jpg
pro-img/08 GM700/En/05_box.jpg
  • Wide HCT range

    Wide HCT range

    Measures glucose value from hematocrit range including anemia, neonatal etc.

  • Replaceable Strip Holder

    Replaceable strip holder

    Eliminates the contamination caused by blood samples handling through convenient strip holder exchange.

  • Insufficient blood sample warning

    Insufficient blood sample warning

    An insfficient blood sample will result in an error message 'Er4'.

  • Multiple blood sample

    Multiple blood sample

    Capillary, venous, arterial and neonatal whole blood are applicable.

  • Auto coding

    Auto coding

    Eliminates the needs for manual coding and delivers better accuracy than no coding.

  • Easy-to-read display

    Easy-to-read display

    Large display and text is easy to read.

  • 1
    Insert the strip in the socket of the meter, which will do calibration automatically.
  • 2
    While the blood drop symbol flashing, please apply a tiny blood sample.
  • 3
    After 5 seconds, the test result appears.
  • 4
    Rotate and pull up the test strip.
Test strip GS700
Accuracy Glucose concentrations < 100mg/dL (5.5mmol/L), error within ± 15mg/dL (0.83mmol/L)
Glucose concentrations ≧ 100mg/dL (5.5mmol/L), error within ± 15%
Precision Glucose concentrations < 100mg/dL (5.5mmol/L), SD < 5mg/dL
Glucose concentrations ≧ 100mg/dL (5.5mmol/L), CV < 5%
Coding Auto coding calibration
Enzyme / Measurement technology GDH / Electrochemical sensor
Blood sample source Capillary, venous, arterial and neonatal whole blood
Minimum sample volume 0.75 microliters  (0.00075c.c.)
HCT range Glucose concentrations ≦ 200mg/dL, HCT range 20 - 70%
Glucose concentrations > 200mg/dL, HCT range 20 - 60%
Measuring range 10 - 600mg/dL (0.6 - 33.3 mmol/L)
Meter dimensions (L x W x H) 99.0 x 46.0 x 17.5 mm (3.89 x 1.81 x 0.68 inch)
Display area (L x W) 52.6 x 32.0 mm (2.07 x 1.25 inch)
Weight (with battery) 57.0 ± 5 g
Power supply 1 CR2032 batteries
Memory capacity 1,000 blood glucose test results with date and time
Operating temperature 6 - 44℃ (43 - 111°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 - 60°C (14 - 140°F)
Test strip storage conditions 4 - 30°C (39 - 86°F), < 90% relative humidity

Fully comply with ISO 15197:2013 and FDA approval (For other received credentials, please contact us.)