GT333

Rightest Glucose Meter

GT333

Bluetooth-Enabled Style

The GT333 gives rapid test results which can be transmitted to the Rightest CARE App thanks to its inbuilt Bluetooth connectivity.

Full compliance with ISO 15197: 2013

/ISO15197_2013CEFDAIVD

pro-img/GT333/en/01_GT333_mmol.jpg
pro-img/GT333/en/02_GT333_mmol.jpg
pro-img/GT333/en/03_GT333.jpg
pro-img/GT333/en/04_GD500.jpg
  • proimages/pro-icons/website_icon-11.png

    Meal Markers

    Record and compare pre- and post-prandial results to understand how food affects your blood glucose.

  • proimages/pro-icons/website_icon-14.png

    Bluetooth Connectivity

    Easy, wireless data transfer.

  • proimages/pro-icons/website_icon-02.png

    Side-Insert Design

    Easy to handle and prevents blood contact for excellent hygiene. 

  • proimages/pro-icons/website_icon-05.png

    Auto-Coding

    Eliminates the need for manual coding and delivers maximum accuracy.

  • proimages/pro-icons/website_icon-46.png

    Trusted Accuracy

    Utilizes gold electrodes and a patented strip structure to provide accurate and reliable results.

Sync with Rightest CARE App

Glucose Management Made Simple

  • 1 proimages/pro-step/25_GT333/01_GT333-Step.jpg
    Insert the strip into the socket of the meter. Calibration will occur automatically.
  • 2 proimages/pro-step/25_GT333/02_GT333-Step.jpg
    Touch a blood sample against the sample entry port of the strip.
  • 3 proimages/pro-step/25_GT333/03_GT333-Step.jpg
    After 5 seconds, the test result will appear.
  • 4 proimages/pro-step/25_GT333/04_GT333-Step_en.jpg
    Rotate and pull upwards to remove the test strip.
Test strip GT333
Coding Auto-coding
Enzyme / Measurement technology GOD / Electrochemical sensor
Blood sample source Capillary whole blood (finger, palm and forearm)
Minimum sample volume 0.75 µL
HCT range 20 - 60%
Measuring range 0.6 - 33.3 mmol/L (10 - 600 mg/dL)
Meter dimensions (L x W x H) 85.0 x 57.0 x 22.5 mm
Display area (L x W) 39.0 x 39.5 mm
Weight (with battery) 81.0 g
Power supply 2 × AAA batteries
Memory capacity 500 blood glucose test results with date and time
Operating temperature 10 - 40°C (50 - 104°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 - 60°C (14 - 140°F)
Test strip storage conditions 4 - 30°C (39 - 86°F), <90% relative humidity
Bluetooth version 4.0
Accuracy 95% of the measured glucose values shall fall within either
Glucose concentrations < 5.5 mmol/L (100 mg/dL), difference within ± 0.83 mmol/L (15 mg/dL)
Glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), bias within ± 15%
Precision Glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL)
Glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5%

Fully compliant with ISO 15197:2013. (For other received credentials, please contact us.)