Max Series

Rightest glucose meter

Max Series

Well-Managed Diabetes, Make your Life Smarter

With intuitive interface design and Bluetooth transmission, let your blood glucose measurement be easy as snapping fingers!
ISO15197_2013CEISO13485_2016IVD

pro-img/06_Max/en/01-max-plus.jpg
pro-img/06_Max/en/02-max-plus.jpg
pro-img/06_Max/en/01-max.jpg
pro-img/06_Max/en/02-max.jpg
pro-img/06_Max/en/03-max-strip.jpg
pro-img/06_Max/en/04-GD500.jpg
pro-img/06_Max/en/05-box.jpg
  • Bluetooth transmission

    Bluetooth transmission (For Max Plus)

    Transfer test results to smartphones wirelessly.

  • Wide HCT range

    Wide HCT range

    Measures glucose value of extreme hematocrit range, like neonate, elder, anemia patient.

  • Multiple blood sample

    Multiple blood sample

    Capillary, venous, arterial and neonatal whole blood are applicable.

  • Auto coding

    Auto coding

    Eliminates the needs for manual coding and delivers better accuracy than no coding.

  • Backlight

    Status marker

    Intuitive markers for time status, exercise and ‘before’ or ‘after’ a meal.

  • Easy-to-read display

    Ketone alert

    Understand ketone notice at a glance.

Markers

  • Wake up
  • Exercise
  • Bedtime
  • Midnight
  • Before meal
  • After meal

Glucose Variability

  • Hyper
  • Normal
  • Hypo

With Rightest Bluetooth glucometer

Manage blood glucose and maintain health easily

  • 1
    Insert the strip in the socket of the meter, which will do calibration automatically.
  • 2
    Place blood sample against the sample entry of strip.
  • 3
    After 5 seconds, the test result appears.
  • 4
    Rotate and pull up the test strip.
Test strip Max Strip
Coding Auto coding
Enzyme / Measurement technology GDH / Electrochemical sensor
Blood sample source Capillary, venous, arterial and neonatal whole blood
Minimum sample volume 0.75 microliters  (0.00075c.c.)
HCT range 10 - 70%
Measuring range 0.6 - 33.3mmol/L (10 - 600mg/dL)
Meter dimensions (L x W x H) 82.0 x 50.0 x 15.5 mm (3.23 x 1.97 x 0.61 inch)
Display area (L x W) 40.7 x 40.2 mm (1.60 x 1.58 inch)
Weight (with battery) 59.0 ± 5 g
Power supply 2 CR2032 battery
Memory capacity 500 blood glucose test results with date and time
Operating temperature 6 - 44°C (43 - 111°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 - 60°C (14 - 140°F)
Test strip storage conditions 4 - 30°C (39 - 86°F), < 90% relative humidity
Bluetooth version (For Max Plus) 4.0
Accuracy 95% of the measured glucose values shall fall within either
Glucose concentrations < 5.5mmol/L (100mg/dL), difference within ± 0.83mmol/L (15mg/dL)
Glucose concentrations ≥ 5.5mmol/L (100mg/dL), bias within ± 15%
Precision Glucose concentrations < 5.5mmol/L (100mg/dL), SD < 0.28mmol/L (5mg/dL)
Glucose concentrations ≥ 5.5mmol/L (100mg/dL), CV < 5%

Fully comply with ISO 15197:2013 (For other received credentials, please contact us.)

  • Getting Started Guide
  • User's Manual
  • Test Strip Guide
  • Instruction for Lancing Device