GE200

GE Glucose Meter

GE200

A Cost-Effective Meter with High Accuracy and Precision

The GE200 is an excellent meter for those looking for reliable readings on a budget. GE200 strips utilize a GDH reagent which eliminates interfering substances.

Full compliance with ISO 15197: 2013

/ISO15197_2013FDAISO13485_2016IVD

pro-img/GE_product/GE200.jpg
pro-img/GE_product/GE200-1.jpg
pro-img/GE_product/GE200-2.jpg
  • proimages/pro-icons/website_icon-05.png

    Auto-Coding

    Eliminates the need for manual coding and delivers maximum accuracy

  • proimages/pro-icons/website_icon-45.png

    Large Display

    Easy to view results.

  • proimages/pro-icons/website_icon-02.png

    Side-Insert Design

    Easy to handle and prevents blood contact for excellent hygiene. 

  • proimages/pro-icons/website_icon-04.png

    Tiny Blood Sample

    Requires only 0.75µL.

  • proimages/pro-icons/website_icon-46.png

    Trusted Accuracy

    Utilizes gold electrodes and a patented strip structure to provide accurate and reliable results.

  • 1
    Insert the strip into the socket of the meter. Calibration will occur automatically.
  • 2
    Touch a blood sample against the sample entry port of the strip.
  • 3
    After 5 seconds, the test result will appear.
  • 4
    Rotate and pull upwards to remove the test strip.
Test strip GE200
Coding Auto-coding
Enzyme / Measurement technology GOD / Electrochemical sensor
Blood sample source Capillary whole blood (finger, palm and forearm)
Minimum sample volume 0.75 µL
HCT range 20 - 60%
Measuring range 0.6 - 33.3 mmol/L (10 - 600mg/dL)
Meter dimensions (L x W x H) 98.0 x 46.0 x 17.5 mm (3.86 x 1.81 x 0.69 inch)
Display area (L x W) 53.0 x 32.0 mm (2.09 x 1.26 inch)
Weight (with battery) 53.0 ± 5 g
Power supply 1 × CR2032 battery
Memory capacity 500 blood glucose test results with date and time
Operating temperature 10 - 40°C (50 - 104°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 - 60°C (14 - 140°F)
Test strip storage conditions 4 - 30°C (39 - 86°F), < 90% relative humidity
Accuracy 95% of the measured glucose values shall fall within either
Glucose concentrations < 5.5mmol/L (100mg/dL), difference within ± 0.83mmol/L (15mg/dL)
Glucose concentrations ≥ 5.5mmol/L (100mg/dL), bias within ± 15%
Precision Glucose concentrations < 5.5mmol/L (100mg/dL), SD < 0.28mmol/L (5mg/dL)
Glucose concentrations ≥ 5.5mmol/L (100mg/dL), CV < 5%

Fully compliant with ISO 15197:2013. (For other received credentials, please contact us.)