GM550

Rightest Glucose Meter

GM550

A High-End Model with Advanced Functions

With proprietary auto-coding technology, a backlit display for reading in the dark, and other advanced functions, the GM550 provides users with accurate results and a hassle-free experience for optimal diabetes management.

Full compliance with EN ISO 15197: 2015 and ISO 15197: 2013

CEFDACFDAISO13485_2016IVD

pro-img/09 GM550/En/01_GM550_mmol.jpg
pro-img/09 GM550/En/02_GM550_mmol.jpg
pro-img/09 GM550/En/03_GS550.jpg
pro-img/09 GM550/En/04_GD500.jpg
pro-img/09 GM550/En/05_box.jpg
pro-img/09 GM550/En/06_GM550_mmol.jpg
  • Fast Results

    Fast Results

    Displayed in 5 seconds.

  • Large Display

    Large Display

    Easy to view results.

  • Auto-Coding

    Auto-Coding

    Eliminates the need for manual coding and delivers maximum accuracy.

  • Tiny Blood Sample

    Tiny Blood Sample

    Requires only 0.75µL.

  • Backlit Screen

    Backlit Screen

    Allows testing in the dark.

  • Side-Insert Design

    Side-Insert Design

    Easy to handle and prevents blood contact for excellent hygiene.

  • 1
    Insert the strip into the socket of the meter. Calibration will occur automatically.
  • 2
    Touch a blood sample against the sample entry port of the strip.
  • 3
    After 5 seconds, the test result will appear.
  • 4
    Rotate and pull upwards to remove the test strip.
Test strip GS550
Coding Auto-coding
Enzyme / Measurement technology GOD / Electrochemical sensor
Blood sample source Capillary whole blood
Minimum sample volume 0.75 µL
HCT range 30 - 57%
Measuring range 0.6 - 33.3 mmol/L (10 - 600 mg/dL)
Meter dimensions (L x W x H) 90.6 x 46.0 x 16.5 mm (3.56 x 1.81 x 0.64 inch)
Display area (L x W) 46.6 x 33 mm (1.83 x 1.32 inch)
Weight (with battery) 53.0 ± 5 g
Power supply 2 × CR2032 batteries
Memory capacity 500 test results with date and time
Operating temperature 10 - 40°C (50 - 104°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 - 60°C (14 - 140°F)
Test strip storage conditions At 4 - 30°C (39 - 86°F), and below 90% relative humidity
Accuracy For glucose concentrations < 5.5 mmol/L (100 mg/dL),
95% of measured glucose values within ± 0.83 mmol/L (15 mg/dL) of reference measurements.
For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL),
95% of measured glucose values within ± 15% of reference measurements.
Precision For glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL)
For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5%

Fully compliant with ISO 15197:2013. (For other received credentials, please contact us.)