GT200

Rightest Glucose Meter

GT200

Stay In Control 

The GT200 is a low budget meter featuring strips with GDH reagent to eliminate interfering substances.

Full compliance with ISO 15197: 2013

ISO15197_2013CEfda_wiz-plus_rightestIVD

pro-img/GT200/en/01_GT200_mmol.jpg
pro-img/GT200/en/02_GT200_mmol.jpg
pro-img/GT200/en/03_GT200.jpg
pro-img/GT200/en/04_GD500.jpg
  • proimages/pro-icons/website_icon-05.png

    Auto-Coding

    Eliminates the need for manual coding and delivers maximum accuracy.

  • proimages/pro-icons/website_icon-09.png

    Large Backlit Screen

    Allows testing in the dark.

  • proimages/pro-icons/website_icon-02.png

    Side-Insert Design

    Easy to handle and prevents blood contact for excellent hygiene. 

  • proimages/pro-icons/website_icon-10.png

    Wide HCT range

    Suitable for neonatal and anemic patients.

  • proimages/pro-icons/website_icon-13.png

    Various Blood Samples Accepted

    Allows capillary, venous and arterial blood.

  • proimages/pro-icons/website_icon-46.png

    Trusted Accuracy

    Utilizes gold electrodes and a patented strip structure to provide accurate and reliable results.

  • 1 proimages/pro-step/24_GT200/01_GT200-Step.jpg
    Insert the strip into the socket of the meter. Calibration will occur automatically.
  • 2 proimages/pro-step/24_GT200/02_GT200-Step.jpg
    Touch a blood sample against the sample entry port of the strip.
  • 3 proimages/pro-step/24_GT200/03_GT200-Step.jpg
    After 5 seconds, the test result will appear.
  • 4 proimages/pro-step/24_GT200/04_GT200-Step_en.jpg
    Rotate and pull upwards to remove the test strip.
Test strip GT200
Coding Auto-coding
Enzyme / Measurement technology GDH / Electrochemical sensor
Blood sample source Capillary, venous, arterial and neonatal whole blood
Minimum sample volume 0.75 µL 
HCT range Glucose concentrations ≦ 11.1 mmol/L (200 mg/dL), HCT range 20 - 70%
Glucose concentrations > 11.1 mmol/L (200 mg/dL), HCT range 20 - 60%
Measuring range 0.6 - 33.3 mmol/L (10 - 600 mg/dL)
Meter dimensions (L x W x H) 96.0 x 48.0 x 15 mm (3.78 x 1.89 x 0.59 inch)
Display area (L x W) 55.0 x 37.0 mm (2.17 x 1.46 inch)
Weight (with battery) 65.0 g ± 5 g
Power supply 2 × CR2032 batteries
Memory capacity 1000 blood glucose test results with date and time
Operating temperature 10 - 40°C (50 - 104°F)
Operating relative humidity 10 - 90%
Meter storage conditions -10 -60°C (14 - 140°F)
Test strip storage conditions 4 - 30°C (39 - 86°F), < 90% relative humidity
Accuracy 95% of the measured glucose values shall fall within either
Glucose concentrations < 5.5 mmol/L (100 mg/dL), difference within ± 0.83 mmol/L (15 mg/dL)
Glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), bias within ± 15%
Precision Glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL)
Glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5%

Fully compliant with ISO 15197:2013. (For other received credentials, please contact us.)